EVALUATION OF TOTAL DISSOLVED SOLIDS (TDS) IN GROUNDWATER AROUND A POULTRY FARM USING ELECTRICAL RESISTIVITY METHOD AND GEOCHEMICAL METHOD

Authors

  • M. A. Fakunle Department of Physics, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author
  • G. I. Olatona Department of Physics, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author
  • O. O. Alabi Department of Pure and Applied Chemistry, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author
  • J. T. Adeleke Department of Physics, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author
  • O. F. Oladejo Department of Pure and Applied Chemistry, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author
  • W.B. Agbaje Department of Physics, Faculty of Basic and Applied Sciences, Osun State University, Osogbo Author

Keywords:

geochemical technique, Electrical resistivity technique, Total Dissolved Solids

Abstract

Most hands dug wells and boreholes at Isundunrin (a town) in Ejigbo Local Government Area of Osun State, South-West Nigeria were completed without physicochemical analysis of the exploited water. This study aimed at validating the electrical resistivity technique as an alternative to the geochemical technique to identify potential aquifers based on total dissolved solids (TDS). Four Schlumberger
Vertical Electrical Soundings (VES) were carried out very close to four different available hand-dug wells located within the premises of a poultry farm at Isundunrin on the longitude E04o 6ʹ 34ʺ - E04o 15ʹ 46ʺ and latitude N07o 51ʹ 52ʺ - N07o 51ʹ 56ʺ. The apparent resistivity values obtained were later transformed to formation resistivity and layered thicknesses by curve matching and computer iteration. The
formation resistivity was used to determine the TDS levels in the exploited groundwater. When the TDS of the geochemical analyses (GCA) was compared with the TDS from VES results, a strong correlation coefficient of R 2 = 0.875 was obtained, which indicated that the geoelectric sounding can be an alternative technique to geo chemical technique to estimate the TDS level in groundwater. 

         Views | Downloads: 70 / 23

Downloads

Download data is not yet available.

References

Mohammed, R.I., Mohammed, K.I.S.., Tanzina, A.S. S.R., Rabiul, I.T., Barun, K. H., Md. Abdul, K., 2016. A study on Total Dissolved Solids and Hardness Level of Drinking Mineral Water in Bangladesh. American Journal of Applied Chemistry.4 (5): 164 –169. Doi: 10.11648/j.ajac.20160405.11

Oladunjoye, M. A, Olayinka, A. I. and Amidu, S.A., 2011. Geoelectrical Imaging at an abandoned Waste Dumpsite in Ibadan, Southwestern Nigeria. Journal of Applied Sciences. 11: 3755 – 3764.

USEPA, 1998. Total Dissolved Solids Laboratory Method 160.2 cited December 2018: http://www.epa.gov/region09/lab/sop

World Health Organization, 1996. Guideline for drinking water quality, 2nd edition, http//www.who.int/water_sanitation_health.

Davies, S.N., and De Wiest, R.J.M., 1966. Hydrogeology John Wiley and Sons, New York.

USEPA, 2009 2009 Edition of the Drinking Water Standards and Health Advisories EPA 822-R-09-011:10

Gowd, S.S., 2005. Assessment of groundwater quality for drinking and irrigation purposes; A case study of Peddavanka watershed, Anantapur District, Andhra Pradesh, India; Environmental Geology. 48: 702 – 712

Ozcan, H., Ekinci, H., Baba, A., Kavdir, Y., Yuksel, O., and Yigini, Y., 2007. Assessment of the water quality of Trola for the multipurpose usages; Environment Monitoring and Assessment. 130: 389 – 402

Dar, I.A, Sankar, K., Shafi, T., and Dar, M.A., 2011. Investigation of groundwater quality in hard rock terrain using Geo information System. Environment Monitoring and Assessment. 176: 1 – 4

Kelly, W. E.1976. Geoelectric sounding for delineating groundwater contamination. Ground Water, 14: 6 – 10.

Urish, D.W., 1983. The practical application of surface electrical resistivity to detection of groundwater pollution, Groundwater, 21: 144 – 152

Mazac, O., Kelly, W. E. and Landa, I., 1987. Surface geo electrics for groundwater pollution and protection studies. Journal of Hydrology 93: 277 – 294

Rahaman, M.A., 1976. Review of basement Geology of South – western Nigeria, in Geology of Nigeria, edited by Kogbe C. A. 2nd revised edition Elizabethan Publ. Co. Lagos. 41 – 58.

Grant, N. K., 1970. A computation of radiometric ages from Nigeria. Journal of Mining and Geology: 6: 37 – 54.

Orellana, E. and Mooney, H.M., 1966. Master tables and curves for vertical electrical sounding over layered structures, Intersciencia, Madrid, 193.

Archie, G. E., 1942. The electrical resistivity log as an aid in determining some reservoir characteristics. Transactions of the Society of Petroleum Engineers of the American Institute of Mining, Metallurgical, and Petroleum Engineers, 146:54 – 62

Repsold, H., 1989. Well logging in groundwater development. Heise Publisher, Handover, Germany.136

Turcan, A. N. Jr, 1966. Calculation of water quality from electrical logs. Theory and practice. Water Resources Pamphlet, Louisiana Geological Survey, Baton Rouge, 23.

APHA. 1975. Method 208D. Total Non-filterable Residue Dried at 103-105⁰C (Total Suspended Matter) in Standard Methods for the Examination of Water and Wastewater, 14th Edition. American Public health Association. Washington, D.C. 460pp.

USEPA, (2011) Consumer information. www.epa.gov/water/drinking.Water/consumer information.

Standard Organization of Nigeria. 2007. Nigeria standard for drinking water quality, NIS 554: 2007, Abuja 30.

World Health Organization, 2008. Guideline for drinking water quality, 3rd ed., incorporating the first and second addenda, vol. 1, Recommendations, WHO Press Geneva

Drever, J.J., 1988. The geochemistry of natural waters (2 nd edition): Englewood Cliffs, New Jersey, Prentice-Hall, 437.

Salifu, Samuel O., and Akhirevbulu, O. E., 2015. Correlation for predicting TDS and electrical Conductance of Groundwater: Using Electrical Resistivity Method. Journal of Multidisciplinary Engineering Science and Technology (JMEST) ISSN: 3159-0040, 2 (11): 2974 – 2975.

Downloads

Published

2022-03-01

How to Cite

EVALUATION OF TOTAL DISSOLVED SOLIDS (TDS) IN GROUNDWATER AROUND A POULTRY FARM USING ELECTRICAL RESISTIVITY METHOD AND GEOCHEMICAL METHOD. (2022). The Journals of the Nigerian Association of Mathematical Physics, 63, 87 – 92. https://nampjournals.org.ng/index.php/home/article/view/126

Share

Similar Articles

1-10 of 33

You may also start an advanced similarity search for this article.